SANY Genuine Hydraulic Return Filter Element (B222100000233 / 60101256)

Premium SANY genuine hydraulic tank return filter (B222100000233 / 60101256) for legacy -8 and early -9 series excavators. High-precision 10μm glass fiber media.

SANY Genuine Hydraulic Return Filter (B222100000233 / 60101256)

The SANY Genuine Tank-Internal Hydraulic Return Filter (B222100000233 / 60101256) is a critical component for SANY's legacy excavators. Positioned at the end of the main control valve return line, it captures metallic shavings and rubber fragments before they re-enter the reservoir, protecting pump and valve longevity.

Compatibility Warning: B222100000233 and 60101256 are identical. This filter is NOT compatible with part 60200365 ("Gold Label 0365"). Ensure correct selection based on machine generation.

Technical Engineering Specifications

FeatureSpecification
OEM Part NumbersB222100000233 / 60101256
Filtration Rating10μm (Glass Fiber)
Performanceβ₁₀ ≥ 200 (99.7% efficiency)
Dimensions154mm (OD) × 464mm (H)
Collapse Pressure≤ 0.25 MPa
Seal ProfileFluororubber (Viton-grade)

System Protection Roles

  • Contaminant Capture: Removes metallic wear from cylinders and hose debris before oil enters the reservoir.

  • Internal Stability: Prevents pump slippage and control valve spool scratching.

  • Safety Integration: Features an internal check valve to maintain oil column stability during system shutdown.

Fleet Compatibility

Engineered for legacy -8 and early -9 generation SANY fleets:

  • Small/Medium: SY135C-8, SY155C-8, SY210C, SY230C.

  • Heavy Mining: SY215C-8, SY235C-8, SY285C-9, SY305C-9, SY335C-9, SY365C-9, SY385C-9, SY420.

Maintenance & Professional Installation

Guidelines:

  • Preparation: Retract all cylinders fully and bleed tank pressure before opening the cover.

  • Diagnostics: Inspect the old filter for metal shards—large amounts indicate impending pump/motor failure.

  • Seal Change: Always replace the housing O-ring with a new Viton seal.

  • Service Cycle: 500 hours (break-in), then 2000 hours (standard) or 1000–1500 hours (harsh/quarry conditions).

  • Air Purge: Run at low idle for 5 minutes post-installation to vent air before applying load.

Contact & Logistics

Supply Source: Xuzhou Sinoswift Import & Export Co., Ltd.

Support: WhatsApp: +86 13701956981 | Email: [email protected]